Sign In | Join Free | My infospaceinc.com
China Beijing Silk Road Enterprise Management Services Co.,LTD logo
Beijing Silk Road Enterprise Management Services Co.,LTD
People-oriented, good faith service, the pursuit of excellent quality.
Verified Supplier

6 Years

Home > Tower Internals >

2500mm Packed Column Internals Scrubber 50m3 Per Hour Water Distributor In Production

Beijing Silk Road Enterprise Management Services Co.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

2500mm Packed Column Internals Scrubber 50m3 Per Hour Water Distributor In Production

  • 1
  • 2

Certification : ISO 9001

Place of Origin : China

MOQ : 1 unit

Price : Negotiation

Payment Terms : L/C, T/T

Supply Ability : 99 units per month

Delivery Time : 3-5 days

Packaging Details : pallet, wooden box

Product : water distributor

Application : scrubber tower

Plate thickness : 3 mm, 4 mm, 5 mm, 6 mm, etc.

Material : stainless steel, or as per order

Position : On top of packing

type : gravity type

flow rate : as per requirement

Advantage : uniform distribution

Design service : yes

Size : any size as per order

Contact Now

2500 mm scrubber 50 m3 per hour water distributor in production

1. Cutom made water distributor,

Liquid distributor is the most important column internal from a process point of view. It is required to distribute liquid uniformly at the top of packing tower. Meanwhile a liquid distributor must have sufficient gas passage area to avoid high pressure drop or liquid entrainment.

2. Custom made water distributor types:

Column Diameter

mm

Specific liquid load

M3/m2*h

System fouling tendency Turndown ratio Suitable type of liquid distributor
250 - 900 0.75 - 5 Low - medium <10:1

Trough type liquid distributor with sump

Deck type liquid distributor with orifices on drip tubes

5 - 30 Low - medium 2:1

Pan type liquid distributor

Trough type liquid distributor with sump

>30 Low - medium 2:1

Pan type liquid distributor

Trough type liquid distributor with sump

Deck type liquid distributor

>900 0.75 - 5 Low - medium <10:1

Trough type liquid distributor with parting box

Deck type liquid distributor with orifices on drip tubes

5 - 30 Low - medium 2:1

Trough type liquid distributor with sump

Trough type liquid distributor with parting box

Deck type liquid distributor

>30 Low - medium 2:1

Deck type liquid distributor

Trough type liquid distributor with sump


3. Characteristics of custom made water distributor:

Liquid distributor is the most important column internal from a process point of view. It is required to distribute liquid uniformly at the top of packing tower. Meanwhile a liquid distributor must have sufficient gas passage area to avoid high pressure drop or liquid entrainment.

Uniform liquid distribution; Resistance to fouling; Proper trundown capabitity;Low gas pressure drop; Minimum height; Higher cross-mixing capabity.

3. How to choose water distributor?

When we need to select a liquid distributor, we need to consider the tower diameter, flow rate, turndown ratio, available height (in case of revamp) and fouling resistance.

Weir type gravity distributor:

Generally speaking, the weir type gravity distributor is one of the least troublesome distributors. It has excellent trundown capability and can handle large liquid load. However it can usually provide only a limited number of drip points (minimum 30 number of weirs per m2). It is also extremely sensitive to levelness and liquid surface agitation.

Orifice type gravity distributor:

Usually it shows as pan type, deck type or tunnel (trough) type. An orifice pan distributor consists of a pan. There are circular or rectangular risers for vapor flow and perforation for liquid flow in the pan.

Orifice trough type distributors consist of parallel troughs with perforated holes in the bottom for liquid flow. Vapor rises in the space between the troughs. The troughs are often interconnected by cross channels (called as parting box), which help equalize the liquid level in different troughs. This trough type liquid distributors provide more open area for vapor flow and is easier to support.

Orifice type distributor can be designed to have a large number of drip points to provide superior liquid distribution, though it may suffer from corrosion and plugging. Orifices are sized to maintain a minimum liquid head at desired turndown conditions & to avoid distributor overflow during turn up condition. Very small orifice diameters (<4mm) are avoided to prevent fouling.

5. Production of water distributor

2500mm Packed Column Internals Scrubber 50m3 Per Hour Water Distributor In Production

Welcome your contact with your private tower internals plan or ideas!


Product Tags:

2500mm packed column internals

      

50m3 packed column internals

      

packed column internals for water distributor

      
Quality 2500mm Packed Column Internals Scrubber 50m3 Per Hour Water Distributor In Production for sale

2500mm Packed Column Internals Scrubber 50m3 Per Hour Water Distributor In Production Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Beijing Silk Road Enterprise Management Services Co.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)